Multicore Flexible Cables

Products

Multicore Flexible Cables

Swami Cables LLP manufactures Multicore Flexible Cables designed to deliver efficient and reliable power and signal transmission in industrial, commercial, and specialized applications. Featuring multiple stranded copper conductors, these cables combine high electrical conductivity with flexibility, allowing easy routing in control panels, machinery, and dynamic installations. The cables are PVC insulated, ensuring durability, safety, and resistance to heat, moisture, oil, and mechanical stress.

The robust construction of multicore flexible cables makes them ideal for applications requiring multiple electrical circuits within a single cable, reducing clutter and simplifying installation. Available in a range of core configurations, sizes, and voltage ratings, these cables are engineered to meet modern electrical standards while delivering long-term performance and reliability.

Why Choose This Cable

  • Multiple stranded copper cores for high conductivity and flexible wiring
  • Robust PVC insulation for protection against heat, moisture, oil, and abrasion
  • Compact design reduces clutter and simplifies multi-circuit installations
  • Easy routing in tight spaces and control panels
  • Low voltage drop and energy-efficient operation
  • Reliable performance under continuous electrical load

Compliance & Certifications

  • Manufactured in accordance with IS: 694 standards
  • Produced under ISO 9001 certified quality management system
  • Tested as per national and international quality norms

Performance Advantages

  • High flexibility for dynamic and confined installations
  • Consistent conductivity and minimal energy loss across all cores
  • Durable insulation for long-lasting electrical safety
  • Resistant to mechanical stress, heat, chemicals, and moisture
  • Simplifies multi-circuit connections with compact multicore design

Technical Specifications

Conductor Material Electrolytic Copper (Stranded)
Insulation Type PVC (Polyvinyl Chloride)
Core Configuration Multicore (2 cores and above)
Voltage Rating Up to 1100 V
Operating Temperature Up to 70°C
Standard Sizes 2.5 – 10 sq.mm per core (custom sizes available)
Applications Control panels, industrial machines, automation systems, and multi-circuit installations
"SWAMI CABLES” PVC insulated and sheathed multicore flexible cables manufactured with high-quality copper conductors.
Size / Area in Sq.mm. No. & size of wire Nominal Insulation thickness (mm) Overall core Diameter (mm) Sheath thickness (mm) Overall diameter (mm) Max. resistance @20°C (ohm/km) Current rating (Amp.)
2 core 3 core 4 core 2 core 3 core 4 core
0.50 16/0.20 0.60 2.20 0.90 0.90 0.90 6.20 6.60 7.20 39.00 4.00
0.75 24/0.20 0.60 2.50 0.90 0.90 0.90 6.80 7.20 7.90 26.00 7.00
1.00 32/0.20 0.60 2.60 0.90 0.90 0.90 7.00 7.50 8.10 19.50 11.00
1.50 48/0.20 0.60 2.90 0.90 0.90 1.00 7.60 8.10 9.00 13.30 14.00
2.50 80/0.20 0.70 3.50 1.00 1.00 1.00 9.00 9.60 10.50 7.98 19.00
4.00 56/0.30 0.80 4.30 1.00 1.00 1.00 10.60 11.30 12.40 4.95 25.00
6.00 84/0.30 0.80 5.50 1.30 1.30 1.40 13.70 14.00 16.50 3.30 32.00
10.00 140/0.30 1.00 6.70 1.40 1.40 1.40 16.50 18.00 19.00 1.91 45.00
Note: The insulation thickness, sheath thickness, and overall dimensions stated in the table are nominal values. The number of strands and strand diameter are designed to meet the conductor resistance requirements as per IS: 8130/1984, and the cables are manufactured in accordance with IS: 694/2010.
SWAMI CABLES” Copper Conductor, PVC Insulated & Sheathed Multicore Flexible Control Cables
Size in sq. mm. Size in mm. Current Rating Approximate overall diameter of cable (mm)
5 core 6 core  7 core 8 core 10 core 12 core 14 core 16 core 19 core
0.50 16/0.20 4.00 8.30 8.50 8.50 9.30 10.80 11.20 12.00 12.60 13.20
0.75 24/0.20 7.00 9.10 9.50 9.50 10.40 12.20 12.60 13.30 14.20 14.90
1.00 32/0.20 11.00 9.60 9.80 9.80 10.70 12.60 13.00 13.70 14.60 15.60
1.50 48/0.20 14.00 10.30 10.70 10.70 11.90 13.80 14.30 15.20 16.00 17.10
2.50 80/0.20 19.00 11.70 12.70 12.70 14.10 16.60 17.20 18.10 19.30 20.30
4.00 56/0.30 25.00 13.95 15.30 15.30 16.90 20.20 20.70 21.80 23.20 24.50
Note: The Insulation thickness, sheath thickness, and overall dimensions stated in the table are nominal values. The number of strands and strand diameter are designed to meet the conductor resistance requirements as per IS 8130:1984 and comply with IS 694:2010.

Applications

  • Industrial control panels and machinery wiring
  • Automation systems and robotics installations
  • Portable and movable electrical equipment
  • Residential and commercial multi-circuit installations
  • Power distribution in complex electrical systems

Products

Related Products

Our Certifications