Swami Cables LLP’s 4 Core PVC Flat Cables are engineered for reliable power transmission in submersible pump and demanding electrical applications. Manufactured using high-purity annealed copper conductors and premium-grade PVC insulation, these cables deliver excellent electrical efficiency, mechanical strength, and long-term durability. The flat construction ensures easy handling, neat installation, and improved heat dissipation in confined spaces.
Designed to perform consistently under continuous load and submerged conditions, our 4 Core PVC Flat Cables offer superior resistance to moisture, abrasion, oil, and chemicals. Each cable is produced under strict quality controls to ensure dependable performance, safety, and extended service life across residential, agricultural, and industrial installations.
| Core Configuration | 4 Core |
| Conductor Material | Electrolytic Grade Annealed Copper |
| Conductor Construction | Stranded |
| Insulation Type | PVC(Polyvinyl Chloride) |
| Voltage Rating | Up to 1100 V |
| Operating Temperature | Up to 70°C |
| Cable Shape | Flat |
| Standard Sizes | 1.5 / 2.5 / 4.0 / 6.0 sq.mm (custom sizes available) |
| "SWAMI CABLES” copper conductor, PVC insulated and sheathed 4 core flat cable | |||||||||||
| Size / Area in Sq.mm. | No. & size of wire | Nominal Insulation thickness (mm) | Overall core Diameter (mm) | Sheath thickness (mm) | Overall size (W X T) (mm) | Max. resistance @20°C (ohm/km) | Current rating (Amp.) | ||||
| 1.50 | 22/0.30 | 0.60 | 3.00 | 1.00 | 15.5 X 5.5 | 12.10 | 14 | ||||
| 2.50 | 36/0.30 | 0.70 | 3.60 | 1.15 | 18.0 X 6.5 | 7.41 | 18 | ||||
| 4.00 | 56/0.30 | 0.80 | 4.50 | 1.20 | 21.0 X 7.5 | 4.61 | 25 | ||||
| 6.00 | 84/0.30 | 1.00 | 5.20 | 1.40 | 24.2 X 8.0 | 3.08 | 32 | ||||
| 10.00 | 140/0.30 | 1.00 | 6.50 | 1.50 | 29.7 X 9.9 | 1.83 | 45 | ||||
| Note: Insulation thickness, sheath thickness, and overall dimensions provided in the table are nominal values. The number of strands and strand diameter are designed to meet the conductor resistance requirements as per IS 8130:1984, and the cable conforms to IS 694:2010. | |||||||||||
| Rating Factor for Low Voltage:Multiply the full load current of submersible motor by factors given below for different supply voltage & select right cable. | |||||||||||||||
| Voltage | 415 | 400 | 350 | 300 | 275 | 250 | |||||||||
| Rating factor | 1.00 | 1.05 | 1.15 | 1.25 | 1.3 | 1.35 | |||||||||
| Derating Factors:For varying ambient temperatures, apply the relevant derating factor to the motor full load current to ensure proper cable selection. | |||||||||||||
| Ambient Temperature °C | 30 | 35 | 40 | 45 | 50 | ||||||||
| Rating factor | 1.09 | 1.04 | 1.00 | 0.95 | 0.77 | ||||||||